Ductile Iron Flange for R6904, R6905, and R6906 |
 |
|
Installation |
|
Convert To Metric Units
|
Size (in.) |
D |
E |
F |
G |
H |
Flange Thickness |
J |
Bolt Size** for connecting Expansion Joints to CPI & HVAC |
| Holes |
Thread |
B.C.* |
Holes |
Thread |
B.C.* |
B.C. |
Class 125 & 150 ANSI Flanges*** |
| 1 |
4 |
1/2-13 |
3 1/8 |
4 |
5/16-18 |
3 1/8 |
1/4 |
5 1/8 |
4 1/4 |
5/16 |
6 |
1/2 - 13 x 1 |
| 1 1/2 |
13 7/8 |
3 7/8 |
5 7/8 |
5 |
11/32 |
6 3/4 |
1/2 - 13 x 1 1/4 |
| 2 |
5/8-11 |
4 3/4 |
4 3/4 |
3/8 |
6 7/8 |
6 |
7/16 |
8 1/2 |
5/8 - 11 x 1 1/2 |
| 2 1/2 |
5 1/2 |
- |
- |
- |
8 1/8 |
7 |
1/2 |
9 3/8 |
5/8 - 11 x 1 3/4 |
| 3 |
6 |
4 |
5/16-18 |
6 |
8 3/4 |
7 1/2 |
10 |
5/8 - 11 x 1 3/4 |
| 4 |
8 |
7 1/2 |
8 |
7 1/2 |
9 7/8 |
9 |
5/8 |
11 1/8 |
5/8 - 11 x 2 |
| 5 |
3/4-10 |
8 1/2 |
- |
- |
- |
1/2 |
11 1/2 |
10 |
3/4 |
13 |
3/4 - 10 x 2 |
| 6 |
9 1/2 |
8 |
3/8-16 |
9 1/2 |
12 1/2 |
11 |
14 |
3/4 - 10 x 2 |
| 8 |
11 3/4 |
- |
- |
- |
14 3/4 |
13 1/2 |
15/16 |
16 1/4 |
3/4 - 10 x 2 1/2 |
| 10 |
12 |
7/8-9 |
14 1/4 |
17 1/2 |
16 |
1 |
19 |
7/8 - 9 x 2 1/2 |
| 12 |
17 |
5/8 |
20 1/2 |
19 |
22 |
7/8 - 9 x 2 1/2 |
| 14 |
1-8 |
18 3/4 |
CF |
24 11/64 |
21 |
1 3/16 |
27 5/16 |
CF |
| 16 |
16 |
21 1/4 |
27 9/16 |
23 1/2 |
31 1/2 |
| 18 |
1 1/8-7 |
22 3/4 |
29 |
25 |
32 29/32 |
| 20 |
20 |
25 |
31 1/2 |
27 1/2 |
35 7/16 |
| 24 |
1 1/4-7 |
29 1/5 |
35 29/32 |
32 |
1 11/32 |
39 27/32 |
All Dimensions in inches.
* Bolt circle same as 125 and 150 lb. ANSI standard.
** Add bolt diameter to length for stud bolts.
*** Lap-joint flanges may require 1/4" longer bolt in some instances.
CF = Consult Factory
Warning: If components show significant deterioration to abrasion,
damage, or corrosion, the assembly should be removed from service. Failure
to periodically perform inspection for abrasion, damage, or corrosion may
lead to failure and/or rupture of the assembly resulting in property
damage, serious personal injury, or death. |
Bolt Torque Information Bolts should be tightened using the following torques as a guide and with well lubricated threads.
Nominal Expansion Joint Size (inches) |
1 |
1 1/2 |
2 |
2 1/2 |
3 |
4 |
5 |
6 |
8 |
10 |
12 |
Flange Bolt Torque ft.-lbs. |
10 |
15 |
25 |
30 |
40 |
30 |
40 |
60 |
75 |
70 |
75 |
No. of Holes Per Flange |
4 |
4 |
4 |
4 |
4 |
8 |
8 |
8 |
8 |
12 |
12 |
| Note: The values in this table are a guide. In some instances, higher torque may be required. However, excessive torque should be avoided. Do not exceed twice the given values. |
 |
 |
 |
"This page is a machine translation of the source page, which is written in